UniFi Switch Pro 24 PoE

Ubiquiti · PoE access switch, 1U · USW-Pro-24-PoE

Front panel
Port 1 · 1 Gb/s1Port 2 · 1 Gb/s2Port 3 · 1 Gb/s3Port 4 · 1 Gb/s4Port 5 · 1 Gb/s5Port 6 · 1 Gb/s6Port 7 · 1 Gb/s7Port 8 · 1 Gb/s8Port 9 · 1 Gb/s9Port 10 · 1 Gb/s10Port 11 · 1 Gb/s11Port 12 · 1 Gb/s12Port 13 · 1 Gb/s13Port 14 · 1 Gb/s14Port 15 · 1 Gb/s15Port 16 · 1 Gb/s16Port 17 · 1 Gb/s17Port 18 · 1 Gb/s18Port 19 · 1 Gb/s19Port 20 · 1 Gb/s20Port 21 · 1 Gb/s21Port 22 · 1 Gb/s22Port 23 · 1 Gb/s23Port 24 · 1 Gb/s24Port 25 · 10 Gb/s25Port 26 · 10 Gb/s26RESET
Rear panel
USP CONNECTIEC C14

what it is

An access switch for a 19-inch rack, 1U high: twenty-four gigabit ports and two SFP+ 10 Gb/s transceiver slots. Steel chassis, 442 × 285 × 44 mm, weight 4.3 kg. A 1.3-inch touchscreen on the front panel.

All twenty-four ports deliver PoE — but not equally. The first sixteen give up to 30 W per port, the last eight up to 60 W. The total budget is 400 W with a 450 W power supply; the switch itself takes up to 50 W before anything is plugged in to draw power.

This is a device for a place where a single panel carries both small loads and devices that will not accept light power: a PTZ camera with a heater, an access point with four radios, a phone with a large display.

It has a backup power input (a DC socket on the rear panel, with its own switch) — meaning a mains power outage does not have to take down a whole floor. This distinguishes it from the smaller models of this family, which do not have such an input.

Watch the name — and this is more serious here than usual. The same family includes the USW-Pro-24, without the word "PoE". The vendor datasheets give for both devices identical dimensions, identical port layout and the same form factor — the only difference is that the other one has no PoE at all. The front panel looks the same.

what we read from it

The state of each of the twenty-six ports separately.

port layout

The twenty-four copper ports are arranged in two rows of twelve, divided into two blocks of six columns. Numbering runs down, then to the right: 1, 3, 5… on top and 2, 4, 6… on the bottom.

The gap between the blocks falls between 12 and 13, and the power boundary between 16 and 17. These are not the same line: ports 1–16 give up to thirty watts, ports 17–24 up to sixty. The power division is recognized by the markings next to the numbers, not by the frame.

At the right edge there are two SFP+ 10 Gb/s transceiver slots side by side — ports 25 and 26. The touchscreen is at the left edge, the reset hole at the right. Each port has LED windows for speed and activity.

On the rear panel there are two inlets: the backup power socket with its own switch on the left and the mains power inlet on the right. There is no console port.

what to watch out for

what we cannot read

transceivers tested in this device

Transceivers we checked in this device, and whether the device showed their optical diagnostics (temperature, power, alarm thresholds):

All transceivers and switches in one place, with filters: what each device shows.

full list of parameters read via SNMP

These are objects the device itself returns over SNMP (names from MIB files). There are no values here, and no port numbers either.

102 parameters

parametertype
BRIDGE-MIB::dot1dBaseBridgeAddressbinary data
BRIDGE-MIB::dot1dBaseNumPortsinteger
BRIDGE-MIB::dot1dBasePortinteger
BRIDGE-MIB::dot1dBasePortCircuitOID identifier
BRIDGE-MIB::dot1dBasePortIfIndexinteger
BRIDGE-MIB::dot1dBaseTypeinteger
ENTITY-MIB::entPhysicalAliasother
ENTITY-MIB::entPhysicalAssetIDother
ENTITY-MIB::entPhysicalClassinteger
ENTITY-MIB::entPhysicalContainedIninteger
ENTITY-MIB::entPhysicalDescrtext
ENTITY-MIB::entPhysicalFirmwareRevother
ENTITY-MIB::entPhysicalHardwareRevother
ENTITY-MIB::entPhysicalIsFRUinteger
ENTITY-MIB::entPhysicalMfgNameother
ENTITY-MIB::entPhysicalModelNametext
ENTITY-MIB::entPhysicalNametext
ENTITY-MIB::entPhysicalParentRelPosinteger
ENTITY-MIB::entPhysicalSerialNumtext
ENTITY-MIB::entPhysicalSoftwareRevtext
ENTITY-MIB::entPhysicalVendorTypeOID identifier
IF-MIB::ifAdminStatusinteger
IF-MIB::ifAliastext
IF-MIB::ifConnectorPresentinteger
IF-MIB::ifCounterDiscontinuityTimeother
IF-MIB::ifDescrtext
IF-MIB::ifHCInBroadcastPktscounter
IF-MIB::ifHCInMulticastPktscounter
IF-MIB::ifHCInOctetscounter
IF-MIB::ifHCInUcastPktscounter
IF-MIB::ifHCOutBroadcastPktscounter
IF-MIB::ifHCOutMulticastPktscounter
IF-MIB::ifHCOutOctetscounter
IF-MIB::ifHCOutUcastPktscounter
IF-MIB::ifHighSpeedinteger
IF-MIB::ifInBroadcastPktscounter
IF-MIB::ifInDiscardscounter
IF-MIB::ifInErrorscounter
IF-MIB::ifInMulticastPktscounter
IF-MIB::ifInNUcastPktscounter
IF-MIB::ifInOctetscounter
IF-MIB::ifInUcastPktscounter
IF-MIB::ifInUnknownProtoscounter
IF-MIB::ifIndexinteger
IF-MIB::ifLastChangeother
IF-MIB::ifLinkUpDownTrapEnableinteger
IF-MIB::ifMtuinteger
IF-MIB::ifNametext
IF-MIB::ifOperStatusinteger
IF-MIB::ifOutBroadcastPktscounter
IF-MIB::ifOutDiscardscounter
IF-MIB::ifOutErrorscounter
IF-MIB::ifOutMulticastPktscounter
IF-MIB::ifOutNUcastPktscounter
IF-MIB::ifOutOctetscounter
IF-MIB::ifOutUcastPktscounter
IF-MIB::ifPhysAddressbinary data
IF-MIB::ifPromiscuousModeinteger
IF-MIB::ifSpeedinteger
IF-MIB::ifTypeinteger
IP-MIB::ipAdEntAddrIP address
IP-MIB::ipAdEntBcastAddrinteger
IP-MIB::ipAdEntIfIndexinteger
IP-MIB::ipAdEntNetMaskIP address
IP-MIB::ipAdEntReasmMaxSizeinteger
Q-BRIDGE-MIB::dot1qVlanForbiddenEgressPortsbinary data
Q-BRIDGE-MIB::dot1qVlanStaticEgressPortsbinary data
Q-BRIDGE-MIB::dot1qVlanStaticNametext
Q-BRIDGE-MIB::dot1qVlanStaticRowStatusinteger
Q-BRIDGE-MIB::dot1qVlanStaticUntaggedPortsbinary data
SNMPv2-MIB::sysContactother
SNMPv2-MIB::sysDescrtext
SNMPv2-MIB::sysLocationother
SNMPv2-MIB::sysNametext
SNMPv2-MIB::sysObjectIDOID identifier
SNMPv2-MIB::sysServicesinteger
SNMPv2-MIB::sysUpTimeother
oid:1.0.8802.1.1.2.1.4.1.1.10text
oid:1.0.8802.1.1.2.1.4.1.1.11binary data
oid:1.0.8802.1.1.2.1.4.1.1.12binary data
oid:1.0.8802.1.1.2.1.4.1.1.4integer
oid:1.0.8802.1.1.2.1.4.1.1.5binary data
oid:1.0.8802.1.1.2.1.4.1.1.6integer
oid:1.0.8802.1.1.2.1.4.1.1.7text
oid:1.0.8802.1.1.2.1.4.1.1.8text
oid:1.0.8802.1.1.2.1.4.1.1.9text
oid:1.3.6.1.2.1.1.8other
oid:1.3.6.1.2.1.1.9.1OID identifier
oid:1.3.6.1.2.1.10.7.2.1.1integer
oid:1.3.6.1.2.1.10.7.2.1.10counter
oid:1.3.6.1.2.1.10.7.2.1.11counter
oid:1.3.6.1.2.1.10.7.2.1.13counter
oid:1.3.6.1.2.1.10.7.2.1.16counter
oid:1.3.6.1.2.1.10.7.2.1.2counter
oid:1.3.6.1.2.1.10.7.2.1.3counter
oid:1.3.6.1.2.1.10.7.2.1.4counter
oid:1.3.6.1.2.1.10.7.2.1.5counter
oid:1.3.6.1.2.1.10.7.2.1.6counter
oid:1.3.6.1.2.1.10.7.2.1.7counter
oid:1.3.6.1.2.1.10.7.2.1.8counter
oid:1.3.6.1.2.1.10.7.2.1.9counter
oid:1.3.6.1.4.1.4413.1.1text

SNMP list source: reading of 1 unit (as of 2026-10-18).