Ubiquiti OM-SM-1G-S

Ubiquiti · SFP transceiver, 1000BASE-BX · OM-SM-1G-S

Transceiver SM · 1 fiber (BiDi)
SM · 1G1 fiber · BiDiblue: TX 1310 → RX 1550 nmyellow: TX 1550 → RX 1310 nmpair: same PN, opposite variant

what it is

A 1000BASE-BX transceiver (Ubiquiti) in the SFP form factor, part number OM-SM-1G-S. Works over a single single-mode (SM) fiber (BiDi): blue latch: TX 1310 / RX 1550 nm; yellow latch: TX 1550 / RX 1310 nm — the pair is the same part number in the opposite variant. Reach per manufacturer: 3 km. Revisions seen in the examined units: A1. Units examined: 2.

what we read from it

The transceiver has optical diagnostics (DOM): the switch reads temperature, supply voltage, laser bias current, transmit power and receive power from it. This makes an aging laser or a dirty connector visible before the link starts losing data.

Reading confirmed in switches: UniFi Switch Enterprise 24 PoE and UniFi Switch Aggregation Pro.

how we checked

The result depends on what the transceiver was read with — the same switch model in a different installation can show different data. That is why each reading is recorded separately:

The same transceiver in other switches and a comparison with other models: what each device shows.

what we cannot read

parameters the transceiver returns

The list shows WHAT the device exposes — including parameters we do not use ourselves. There are no values here at all: it is a catalog of capabilities, not a reading from anyone's network. It is not a closed list either — explanation below the table.

11 parameters

parametertype
moc_nadawananumber (dBm)
moc_odbierananumber (dBm)
napiecie_zasilanianumber (V)
numer_czescitext — part number (PN)
numer_seryjnytext
prad_laseranumber (mA)
producenttext — vendor name from transceiver memory
rewizjatext
temperaturanumber (°C)
usterka_nadajnika_tx_faultboolean
zgodnosctext — standard (e.g. 1000BASE-LX)

This is not a closed list. It comes from reading a unit we had access to — it shows what we managed to retrieve, not everything the device can return. A different firmware version, hardware variant or reading path can expose fields that are not here. If you are interested in a specific unit and a specific value — please ask; there is a good chance it can be obtained, even if you do not see it below.

List source: reading of 2 working units (as of 2026-10-19). The list is the sum of what we observed — more units reveal more parameters, so numbers for different models are not directly comparable.