Finisar FTLF8519P3BNL-CS

Finisar · SFP transceiver, 1000BASE-SX · FTLF8519P3BNL-CS

Transceiver MM · 2 fibers (duplex)
MM · 1G2 fibers · duplex850 nm

what it is

A 1000BASE-SX transceiver (Finisar) in the SFP form factor, part number FTLF8519P3BNL-CS. Works over two multimode (MM) fibers (duplex), 850 nm. Reach per manufacturer: OM2 550 m, OM1 270 m. Wavelength from the transceiver memory: 850 nm. Production year stored in memory: 2016. Revisions seen in the examined units: A. The switch reports it as GLC-SX-MMD. Units examined: 3.

what we read from it

The transceiver has optical diagnostics (DOM): the switch reads temperature, supply voltage, transmit power and receive power from it. This makes an aging laser or a dirty connector visible before the link starts losing data.

Reading confirmed in switches: Cisco WS-C3750X-12S-S.

A full read of the transceiver memory gives it a diagnostics score of 9 out of 15 — counted are: presence of measurements, manufacturer thresholds, alarm flags set by the transceiver itself and software loss-of-signal indication.

what the transceiver memory declares

Transceiver memory read directly from a Cisco switch (show idprom, page A0) — 3 units. Each item gives the memory byte and value it comes from; we do not show serial numbers, exact dates or the vendor-reserved area.

A declaration in memory is not the same as a reading: diagnostic measurements were shown by Cisco WS-C3750X-12S-S.

how we checked

The result depends on what the transceiver was read with — the same switch model in a different installation can show different data. That is why each reading is recorded separately:

The same transceiver in other switches and a comparison with other models: what each device shows.

what we cannot read

parameters the transceiver returns

The list shows WHAT the device exposes — including parameters we do not use ourselves. There are no values here at all: it is a catalog of capabilities, not a reading from anyone's network. It is not a closed list either — explanation below the table.

18 parameters

parametertype
data_produkcjidate
dlugosc_fali_nmnumber (nm)
moc_nadawananumber (dBm)
moc_odbierananumber (dBm)
napiecie_zasilanianumber (V)
numer_czescitext — part number (PN)
numer_seryjnytext
oui_producentatext — chip vendor identifier
producenttext — vendor name from transceiver memory
progi_alarmow_i_ostrzezennumbers — vendor thresholds for 5 values
rewizjatext
rewizja_sff8472text — diagnostics standard revision
sumy_kontrolneboolean — transceiver memory validity
temperaturanumber (°C)
utrata_swiatla_rx_losboolean
wylaczenie_nadajnika_tx_disableboolean
zasiegi_wlokiennumbers (m / km) for OM1–OM3 and single-mode fiber
zgodnosctext — standard (e.g. 1000BASE-LX)

This is not a closed list. It comes from reading a unit we had access to — it shows what we managed to retrieve, not everything the device can return. A different firmware version, hardware variant or reading path can expose fields that are not here. If you are interested in a specific unit and a specific value — please ask; there is a good chance it can be obtained, even if you do not see it below.

List source: reading of 3 working units (as of 2026-10-19). The list is the sum of what we observed — more units reveal more parameters, so numbers for different models are not directly comparable.